Trench Grate & Frame

g.bmp (119870 bytes)      Class F & G : 900 kN test load  f.bmp (136222 bytes)

Safe Working Loads:

  • Airport Taxiways.
  • Airport aprons, terminal areas.

 

Havestock Class F & G Trench Grate & Frame
Code Width mm Length mm Weight kg
LG30G 300 610 85
TG30GC (CELLULAR FRAME) 300 610 62

Only available as : Cellular Frame with Transverse Bar

 

Overall Frame Size 

Frame Depth 120mm
Overall Frame Width Clear opening width + 160mm
Overall Frame Length Clear opening length

Overall Grate Size

Grate Depth 60mm
Overall Grate Width Clear opening width + 70mm
Overall Grate Length Clear opening length

Installation

Class F & G grates and frames; the product must not be rebated into position. The product must be cast into the base concrete.

  • Care must be taken to ensure that concrete is vibrated, particularly under the frame and that concrete both under the frame and inside the cellular frame structure reaches the same Mpa as the base concrete.
  • Clear opening of the pit must not be larger than the frame opening.
  • The product must be built into the base concrete and the base concrete must include sufficient reinforcing under and around the frame and in some cases reinforcing must be attached to the frame (ie cases of high back pressure head).
  • As the manufacturer of the cast iron product, we advise that whilst our product is tested to AS3996 in terms of design load, the frames are designed to be fully encased in concrete of sufficient Mpa to hold the loads indicated.
  • Havestock Pty Ltd takes no responsibility for the integrity of the product in service where it has not been installed as described in this document. Inadequate installation voids the product warranty.

 